设为首页 加入收藏 登录旧版
10 mL斜面注射器针头在关节镜下顽固性跖筋膜炎的松解并骨刺切除术的应用
Application of 10 mL beveled syringe needle in arthroscopic calcaneal spur resection in the treatment of refractory metatarsal fasciitis
投稿时间:2024-07-29  
DOI:10.3969/j.issn.1672-5972.2025.03.011
中文关键词:  斜面针头  关节镜  跟骨骨刺切除术  跟骨骨刺  跟痛症  顽固性跖筋膜炎
英文关键词:Bevel needle  Arthroscopy  Calcaneal spur resection  Calcaneal spurs  Heel pain  Refractory plantar fasciitis
基金项目:
作者单位邮编
黄高鹏* 海盐邦尔医院骨科浙江 嘉兴314399 314399
薛文谦 海盐邦尔医院骨科浙江 嘉兴314399 314399
陈伟伟 海盐邦尔医院骨科浙江 嘉兴314399 314399
摘要点击次数: 11
全文下载次数: 3
中文摘要:
      目的 探讨关节镜下跟骨骨刺切除术治疗顽固性跖筋膜炎中10 mL斜面注射器针头的应用价值。方法 选取自2020年7月至2024年1月因跟痛症在海盐邦尔医院就诊的患者,经诊断为顽固性跖筋膜炎伴有跟骨骨刺,根据患者意愿行关节镜下跖筋膜松解与跟骨骨刺切除术43例,术中均采用10 mL斜面注射器针头辅助跟骨骨刺定位和关节镜人工腔内生理盐水引流。记录患者的手术时间、恢复下地行走时间、并发症、切口愈合程度,通过VAS评分、AOFAS评分和Maryland评分对患者术后足部疼痛程度和足部功能进行评价。结果 所有患者均获得随访,随访时间6 ~ 9个月,且随访期间均无其他并发症发生且未见骨刺复发。所有患者顺利完成手术,手术时间20 ~ 45 min,术后2 ~ 4 d首次下地行走。术后1例患者出现足跟部残留少许疼痛,其余患者围手术期未见切口开裂、感染、延迟愈合等并发症。手术切口均为2个长度为0.5 cm的切口,且甲级愈合。术后6个月,患者VAS评分、AOFAS评分和Maryland评分均较术前显著改善,差异有统计学意义(P<0.05)。术后6个月,平均AOFAS评分为(93.49±5.01)分,根据AOFAS评分评定患者的临床效果,优34例,良9例,优良率为100%。结论 采用10 mL斜面注射器针头辅助关节镜下跖筋膜松解与跟骨骨刺切除术安全有效,取材方便,价格低廉,手术医生便于操作,持续保持术野清晰,缩短手术时间,降低手术风险,具有一定的临床应用价值。
英文摘要:
      Objective To investigate the application value of 10 mL beveled syringe needle in arthroscopic calcaneal spur resection in the treatment of refractory metatarsal fasciitis.Methods A total of 43 patients who were diagnosed with refractory plantar fasciitis with calcaneal spur due to heel pain were selected from July 2020 to January 2024, and 43 patients underwent arthroscopic plantar fascia release and calcaneal spur resection according to the patients' wishes, and 10 mL beveled syringe needles were used to assist calcaneal spur positioning and arthroscopic artificial cavity normal saline drainage. The operation time, recovery walking time, complications and incision healing degree were recorded, and the postoperative foot pain and foot function were evaluated by VAS score, AOFAS and Maryland score.Results All patients were followed up for 6 to 9 months, and no other complications occurred during the follow-up period, and no bone spur recurrence was observed. All patients successfully completed the operation with a duration of 20-45 min and the first walk on the ground 2-4 d after surgery. One patient had a little residual pain in the heel after surgery, and the rest of the patients did not have complications such as incision dehiscence, infection, and delayed healing during the perioperative period. The surgical incisions were all 2 incisions with a length of 0.5 cm, and the patients all acquired the grade A healing. At 6 months after surgery, the VAS score, AOFAS and Maryland scores were significantly improved compared with those before operation, and there were statistically significant differences (P<0.05). At 6 months after operation, the average AOFAS score was (93.49±5.01), and the clinical effect of the patients was evaluated according to the AOFAS score, 34 cases were excellent and 9 cases were good, with an excellent and good rate of 100%.Conclusion The use of 10 mL beveled syringe needle to assist arthroscopic arthroscopic plantar fascia release and calcaneal spur resection is safe and effective, convenient to use, low price, easy for surgeons to operate, continuously maintain a clear surgical field, shorten the operation time, reduce the surgical risk, and has certain clinical application value.
查看全文  查看/发表评论  下载PDF阅读器
扫码关注
《生物骨科材料与临床研究》微信公众号